A custom shielding quotation can be difficult to compare when two suppliers use the same word for different parts of the job. Before comparing totals, ask what each term includes and attach the answer to the quotation revision being discussed.
1. Internal dimensions
Ask whether these mean the unobstructed space available for use, a liner dimension, or a nominal enclosure size. A frame, corner detail or service assembly may occupy some space. For a tent around equipment, give the equipment envelope and the required operating clearance separately. For a room, check what space remains after the agreed interior fit-out.
2. Complete enclosure
Ask for the supplied-parts list. A cover may consist of an upper section and a separate base. A tent may include a frame, shielding liner, connected floor and entrance. An outdoor assembly may also require a weather cover and anchoring. The quotation should identify the assembly being supplied, rather than leaving the reader to infer it from an image.
3. Access opening
Confirm the usable opening and the method of closure. Ask which state applies to the stated performance: fully closed, connected to a base, or fitted with particular service components. An open-door photograph illustrates access; it does not demonstrate shielding in that state. Record whether routine access requires removing a cover or only opening a defined entrance.
4. Services included
Make a list of power, signal, data, ventilation and other required crossings. Ask which components are included and which are supplied or installed by others. A hole reserved for a cable is different from a completed interface specified for the agreed shielding objective. An operating machine also needs a review of heat and moving parts.
5. Testing included
Ask what is tested: a material sample, a seam or closure detail, a finished product, or an installed room. The test record should identify the item and configuration, method, frequencies, measurement locations and acceptance criteria appropriate to the project. A material result should not be presented as a finished-enclosure result.
RF and EMP requirements need their respective verification methods. If low-frequency magnetic shielding is needed, name it explicitly for design review. Do not assume that a broad electromagnetic label supplies a missing frequency range or test condition.
6. Installation and delivery
Separate manufacture, packing, freight, unloading, assembly and installation. For a building project, identify site preparation and interior works. For a tent or large cover, check packed sizes, handling arrangements and who assembles it. Ask which destination and access assumptions the price uses.
7. Approval and lead time
Identify the event that starts the quoted lead time. It may depend on an approved drawing, agreed specification, sample review or other commercial milestone. List open technical questions before treating a provisional date as a confirmed delivery commitment. Keep approval responsibility and the quotation revision visible in the record.
Where to start a scope discussion
SignalVault's building and space shielding page describes room retrofits, modular spaces, installation and interior fit-out. SignalVault's vehicle and equipment shielding page covers fitted vehicle covers, shielding tents and equipment enclosure formats.